| Outdoor units |
|
HOP6WODU |
| Heating A7W35 1 |
Power |
kW |
6,20 |
| Energy consumption |
kW |
1,24 |
| COP |
5,00 |
| Heating A7W45 2 |
Power |
kW |
6,35 |
| Energy consumption |
kW |
1,69 |
| COP |
3,75 |
| Heating A7W55 3 |
Power |
kW |
6,00 |
| Energy consumption |
kW |
2,00 |
| COP |
3,00 |
| Heating A-7W35 4 |
Power |
kW |
6,10 |
| Energy consumption |
kW |
2,00 |
| COP |
3,05 |
| Cooling A35W18 5 |
Power |
kW |
6,55 |
| Energy consumption |
kW |
1,34 |
| EER |
4,90 |
| Cooling A35W7 6 |
Power |
kW |
7,00 |
| Energy consumption |
kW |
2,33 |
| EER |
3,00 |
| Energy efficiency class 7 |
Water temperature 35°C |
class |
A+++ |
| Water temperature 55°C |
class |
A++ |
| SCOP 7 |
35°C |
4,95 |
| 55°C |
3,52 |
| SEER 7 |
7°C |
5,37 |
| 18°C |
8,21 |
| Power supply |
V/Ph/Hz |
220-240/1/50 |
| Rated power |
W |
2600 |
| Rated current |
A |
12,0 |
| Automatic switch |
C16 ~1 |
| Power cable |
mm2 |
3x2,5 |
| Refrigerant |
Type (GWP) |
R32 (675) |
| Quantity in the device |
kg |
1,5 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
6,35 (1/4") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Between the indoor and outdoor blocks |
Height difference, max. |
m |
20 |
| Track length, min. |
m |
3 |
| Track length, max. |
m |
30 |
| Refrigerant replenishment |
Quantity |
g/m |
20 |
| Pipe length |
m |
max.15 |
| Compressor |
DC two rotor inverter |
| Fan |
DC electric motor |
| Sound power level 8 |
dB(A) |
58 |
| Sound pressure (at a distance of 1m) 9 |
dB(A) |
45 |
| Sound pressure (1m away, silent mode) 9 |
dB(A) |
40 |
| Dimensions (W x H x D) |
mm |
1008×712×426 |
| Dimension of Package (W x H x D) |
mm |
1065×810×485 |
| Net / Gross weight |
|
kg |
58 / 63.5 |
| Outdoor operating temperature limits |
Heating |
°C |
-25 ~ +35 |
| Cooling |
°C |
-5 ~ +43 |
| Hot water preparation |
°C |
-25 ~ +43 |
| Indoor units with built-in hot water
tank |
HOP100/190IDU |
| Efficiency class for hot potable water treatment
(temperate zone) |
class |
A+ |
| COP |
3,10 |
| Declared load profile |
L |
| Water tank capacity |
Capacity |
l |
190 |
| Material |
- |
Stainless Steel, SUS 316L |
| Max water temperature |
°C |
70 |
| Isolation |
- |
Polyurethane |
| Built-in electric heater |
kW |
3 |
| Power supply |
V/Ph/Hz |
220-240/1/50 |
| Rated power |
W |
3095 |
| Rated current |
A |
13,5 |
| Power cable |
mm2 |
3x2,5 |
| Communication cable, AWG18 shielded |
mm2 |
2x0,75 |
| Sound power level |
dB(A) |
38 |
| Sound pressure 9 |
dB(A) |
ND |
| Dimensions (W x H x D) |
mm |
600x1683x600 |
| Dimension of Package (W x H x D) |
mm |
730x1920x730 |
| Circulation pump |
Type |
DC, electronic |
| Maximum lifting height |
m |
9 |
| Power |
W |
5~90 |
| Minimum water flow |
m3/h |
0,36 |
| Operating limits for water flow |
m3/h |
0,4 ~ 1,25 |
| Heat exchanger |
Plate |
| Expansion tank |
l |
8 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
6,35 (1/4") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Water pipe connection |
Heating/cooling |
R1" |
| Hot water preparation |
R3/4" |
| Net / Gross weight |
|
kg |
140 / 161 |
| Supply water temperature |
Heating |
°C |
+12 ~ +65 |
| Cooling |
°C |
+5 ~ +30 |
| Hot water preparation |
°C |
+12 ~ +60 |
| Ambient temperature |
°C |
+5 ~ +35 |
| Water pressure in the heating/cooling system |
bar |
1 ~ 2,5 |
| Water pressure in the hot water system (cold water) |
bar |
1,5 ~ 3 |
1 Air temperature +7°C, 85% RH, water temperature +30/35°C.2 Air temperature +7°C, 85%
RH, water temperature +40/45°C.3 Air temperature +7°C, 85% RH, water temperature +47/55°C.4 Air temperature -7°C, 85% RH, water temperature +30/35°C.5 Air temperature +35°C, water temperature +23/18°C.6 Air temperature +35°C, water temperature +12/7°C.
7 Determined in temperate climate conditions.
8 Tested according to EN12102-1 standard.
9 The maximum sound pressure value tested under two conditions is A7W35 for heating and A35W18 for
cooling.
| Outdoor units |
|
HOP6WODU |
| Heating A7W35 1 |
Power |
kW |
6,20 |
| Energy consumption |
kW |
1,24 |
| COP |
5,00 |
| Heating A7W45 2 |
Power |
kW |
6,35 |
| Energy consumption |
kW |
1,69 |
| COP |
3,75 |
| Heating A7W55 3 |
Power |
kW |
6,00 |
| Energy consumption |
kW |
2,00 |
| COP |
3,00 |
| Heating A-7W35 4 |
Power |
kW |
6,10 |
| Energy consumption |
kW |
2,00 |
| COP |
3,05 |
| Cooling A35W18 5 |
Power |
kW |
6,55 |
| Energy consumption |
kW |
1,34 |
| EER |
4,90 |
| Cooling A35W7 6 |
Power |
kW |
7,00 |
| Energy consumption |
kW |
2,33 |
| EER |
3,00 |
| Energy efficiency clase 7 |
Water temperature 35°C |
clase |
A+++ |
| Water temperature 55°C |
clase |
A++ |
| SCOP 7 |
35°C |
4,95 |
| 55°C |
3,52 |
| SEER 7 |
7°C |
5,37 |
| 18°C |
8,21 |
| Power supply |
V/Ph/Hz |
220-240/1/50 |
| Rated power |
W |
2600 |
| Rated current |
A |
12,0 |
| Automatic switch |
C16 ~1 |
| Power cable |
mm2 |
3x2,5 |
| Refrigerant |
Type (GWP) |
R32 (675) |
| Quantity in the device |
kg |
1,5 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
6,35 (1/4") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Between the indoor and outdoor blocks |
Height difference, max. |
m |
20 |
| Track length, min. |
m |
3 |
| Track length, max. |
m |
30 |
| Refrigerant replenishment |
Quantity |
g/m |
20 |
| Pipe length |
m |
max.15 |
| Compressor |
DC two rotor inverter |
| Fan |
DC electric motor |
| Sound power level 8 |
dB(A) |
59 |
| Sound pressure (at a distance of 1m) 9 |
dB(A) |
46 |
| Sound pressure (1m away, silent mode) 9 |
dB(A) |
41 |
| Dimensions (W x H x D) |
mm |
1118×865×523 |
| Dimension of Package (W x H x D) |
mm |
1190×970×560 |
| Net / Gross weight |
|
kg |
75 / 89 |
| Outdoor operating temperature limits |
Heating |
°C |
-25 ~ +35 |
| Cooling |
°C |
-5 ~ +43 |
| Hot water preparation |
°C |
-25 ~ +43 |
| Indoor units with built-in hot water
tank |
HOP100/190IDU3 |
| Efficiency class for hot potable water treatment
(temperate zone) |
class |
A+ |
| COP |
3,10 |
| Declared load profile |
L |
| Water tank capacity |
Capacity |
l |
190 |
| Material |
- |
Stainless Steel, SUS 316L |
| Max water temperature |
°C |
70 |
| Isolation |
- |
Polyurethane |
| Built-in electric heater |
kW |
9 (3+3+3)8 |
| Power supply |
V/Ph/Hz |
380-415/3/50 |
| Rated power |
W |
9095 |
| Rated current |
A |
13,5 |
| Power cable |
mm2 |
5x2,5 |
| Communication cable, AWG18 shielded |
mm2 |
2x0,75 |
| Sound power level |
dB(A) |
38 |
| Sound pressure 9 |
dB(A) |
ND |
| Dimensions (W x H x D) |
mm |
600x1683x600 |
| Dimension of Package (W x H x D) |
mm |
730x1920x730 |
| Circulation pump |
Type |
DC, electronic |
| Maximum lifting height |
m |
9 |
| Power |
W |
5~90 |
| Minimum water flow |
m3/h |
0,36 |
| Operating limits for water flow |
m3/h |
0,4 ~ 1,25 |
| Heat exchanger |
Plate |
| Expansion tank |
l |
8 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
6,35 (1/4") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Water pipe connection |
Heating/cooling |
R1" |
| Hot water preparation |
R3/4" |
| Net / Gross weight |
|
kg |
139 / 154 |
| Supply water temperature |
Heating |
°C |
+12 ~ +65 |
| Cooling |
°C |
+5 ~ +30 |
| Hot water preparation |
°C |
+12 ~ +60 |
| Ambient temperature |
°C |
+5 ~ +35 |
| Water pressure in the heating/cooling system |
bar |
1 ~ 2,5 |
| Water pressure in the hot water system (cold water) |
bar |
1,5 ~ 3 |
1 Air temperature +7°C, 85% RH, water temperature +30/35°C.2 Air temperature +7°C, 85% RH,
water temperature +40/45°C.
3 Air temperature +7°C, 85% RH, water temperature +47/55°C.
4 Air temperature -7°C, 85% RH, water temperature +30/35°C.
5 OAir temperature +35°C, water temperature +23/18°C.
6 Air temperature +35°C, water temperature +12/7°C.
7 Determined in temperate climate conditions.
8 Tested according to EN12102-1 standard.
9 The maximum sound pressure value tested under two conditions is A7W35 for heating and A35W18 for
cooling.
| Outdoor units |
|
HOP8WODU |
| Heating A7W35 1 |
Power |
kW |
8,30 |
| Energy consumption |
kW |
1,60 |
| COP |
5,20 |
| Heating A7W45 2 |
Power |
kW |
8,20 |
| Energy consumption |
kW |
2,08 |
| COP |
3,95 |
| Heating A7W55 3 |
Power |
kW |
7,50 |
| Energy consumption |
kW |
2,36 |
| COP |
3,18 |
| Heating A-7W35 4 |
Power |
kW |
7,10 |
| Energy consumption |
kW |
2,18 |
| COP |
3,25 |
| Cooling A35W18 5 |
Power |
kW |
8,40 |
| Energy consumption |
kW |
1,66 |
| EER |
5,05 |
| Cooling A35W7 6 |
Power |
kW |
7,40 |
| Energy consumption |
kW |
2,19 |
| EER |
3,38 |
| Energy efficiency class7 |
Water temperature 35°C |
class |
A+++ |
| Water temperature 55°C |
class |
A++ |
| SCOP 7 |
35°C |
5,22 |
| 55°C |
3,37 |
| SEER 7 |
7°C |
5,83 |
| 18°C |
8,95 |
| Power supply |
V/Ph/Hz |
220-240/1/50 |
| Rated power |
W |
3300 |
| Rated current |
A |
14,5 |
| Automatic switch |
C16 ~1 |
| Power cable |
mm2 |
3x2,5 |
| Refrigerant |
Type (GWP) |
R32 (675) |
| Quantity in the device |
kg |
1,65 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
9,52 (3/8") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Between the indoor and outdoor blocks |
Height difference, max. |
m |
20 |
| Track length, min. |
m |
3 |
| Track length, max. |
m |
30 |
| Refrigerant replenishment |
Quantity |
g/m |
38 |
| Pipe length |
m |
max.15 |
| Compressor |
DC two rotor inverter |
| Fan |
DC electric motor |
| Sound power level 8 |
dB(A) |
59 |
| Sound pressure (at a distance of 1m) 9 |
dB(A) |
46 |
| Sound pressure (1m away, silent mode) 9 |
dB(A) |
41 |
| Dimensions (W x H x D) |
mm |
1118×865×523 |
| Dimension of Package (W x H x D) |
mm |
1190×970×560 |
| Net / Gross weight |
|
kg |
75/89 |
| Outdoor operating temperature limits |
Heating |
°C |
-25 ~ +35 |
| Cooling |
°C |
-5 ~ +43 |
| Hot water preparation |
°C |
-25 ~ +43 |
| Indoor units with built-in hot water tank |
HOP100/190IDU |
| Efficiency class for hot potable water treatment
(temperate zone) |
class |
A+ |
| COP |
3,02 |
| Declared load profile |
L |
| Water tank capacity |
Capacity |
l |
190 |
| Material |
- |
Stainless Steel, SUS 316L |
| Max water temperature |
°C |
70 |
| Isolation |
- |
Polyurethane |
| Built-in electric heater |
kW |
3 |
| Power supply |
V/Ph/Hz |
220-240/1/50 |
| Rated power |
W |
3095 |
| Rated current |
A |
13,5 |
| Power cable |
mm2 |
3x2,5 |
| Communication cable, AWG18 shielded |
mm2 |
2x0,75 |
| Sound power level |
dB(A) |
40 |
| Sound pressure 9 |
dB(A) |
ND |
| Dimensions (W x H x D) |
mm |
600x1683x600 |
| Dimension of Package (W x H x D) |
mm |
730x1920x730 |
| Circulation pump |
Type |
DC, electronic |
| Maximum lifting height |
m |
9 |
| Power |
W |
5~90 |
| Minimum water flow |
m3/h |
0,36 |
| Operating limits for water flow |
m3/h |
0,4 ~ 2,1 |
| Heat exchanger |
Plate |
| Expansion tank |
l |
8 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
9,52 (3/8") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Water pipe connection |
Heating/cooling |
R1" |
| Hot water preparation |
R3/4" |
| Net / Gross weight |
|
kg |
140 / 161 |
| Supply water temperature |
Heating |
°C |
+12 ~ +65 |
| Cooling |
°C |
+5 ~ +30 |
| Hot water preparation |
°C |
+12 ~ +60 |
| Ambient temperature |
°C |
+5 ~ +35 |
| Water pressure in the heating/cooling system |
bar |
1 ~ 2,5 |
| Water pressure in the hot water system (cold water) |
bar |
1,5 ~ 3 |
1 Air temperature +7°C, 85% RH, water temperature +30/35°C.2 Air temperature +7°C, 85% RH, water temperature +40/45°C.
3 Air temperature +7°C, 85% RH, water temperature +47/55°C.
4 Air temperature -7°C, 85% RH, water temperature +30/35°C.
5 OAir temperature +35°C, water temperature +23/18°C.
6 Air temperature +35°C, water temperature +12/7°C.
7 Determined in temperate climate conditions.
8 Tested according to EN12102-1 standard.
9 The maximum sound pressure value tested under two conditions is A7W35 for heating and A35W18 for
cooling.
| Outdoor units |
|
HOP8WODU |
| Heating A7W35 1 |
Power |
kW |
8,30 |
| Energy consumption |
kW |
1,60 |
| COP |
5,20 |
| Heating A7W45 2 |
Power |
kW |
8,20 |
| Energy consumption |
kW |
2,08 |
| COP |
3,95 |
| Heating A7W55 3 |
Power |
kW |
7,50 |
| Energy consumption |
kW |
2,36 |
| COP |
3,18 |
| Heating A-7W35 4 |
Power |
kW |
7,10 |
| Energy consumption |
kW |
2,18 |
| COP |
3,25 |
| Cooling A35W18 5 |
Power |
kW |
8,40 |
| Energy consumption |
kW |
1,66 |
| EER |
5,05 |
| Cooling A35W7 6 |
Power |
kW |
7,40 |
| Energy consumption |
kW |
2,19 |
| EER |
3,38 |
| Energy efficiency class7 |
Water temperature 35°C |
class |
A+++ |
| Water temperature 55°C |
class |
A++ |
| SCOP 7 |
35°C |
5,22 |
| 55°C |
3,37 |
| SEER 7 |
7°C |
5,83 |
| 18°C |
8,95 |
| Power supply |
V/Ph/Hz |
220-240/1/50 |
| Rated power |
W |
3300 |
| Rated current |
A |
14,5 |
| Automatic switch |
C16 ~1 |
| Power cable |
mm2 |
3x2,5 |
| Refrigerant |
Type (GWP) |
R32 (675) |
| Quantity in the device |
kg |
1,65 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
9,52 (3/8") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Between the indoor and outdoor blocks |
Height difference, max. |
m |
20 |
| Track length, min. |
m |
3 |
| Track length, max. |
m |
30 |
| Refrigerant replenishment |
Quantity |
g/m |
38 |
| Pipe length |
m |
max.15 |
| Compressor |
DC two rotor inverter |
| Fan |
DC electric motor |
| Sound power level 8 |
dB(A) |
59 |
| Sound pressure (at a distance of 1m) 9 |
dB(A) |
46 |
| Sound pressure (1m away, silent mode) 9 |
dB(A) |
41 |
| Dimensions (W x H x D) |
mm |
1118×865×523 |
| Dimension of Package (W x H x D) |
mm |
1190×970×560 |
| Net / Gross weight |
|
kg |
75 / 89 |
| Outdoor operating temperature limits |
Heating |
°C |
-25 ~ +35 |
| Cooling |
°C |
-5 ~ +43 |
| Hot water preparation |
°C |
-25 ~ +43 |
| Indoor units with built-in hot water tank |
HOP100/190IDU3 |
| Efficiency class for hot potable water treatment
(temperate zone) |
class |
A+ |
| COP |
3,02 |
| Declared load profile |
L |
| Water tank capacity |
Capacity |
l |
190 |
| Material |
- |
Stainless Steel, SUS 316L |
| Max water temperature |
°C |
70 |
| Isolation |
- |
Poliuretanas |
| Built-in electric heater |
kW |
9 (3+3+3)8 |
| Power supply |
V/Ph/Hz |
380-415/3/50 |
| Rated power |
W |
9095 |
| Rated current |
A |
13,5 |
| Power cable |
mm2 |
5x2,5 |
| Communication cable, AWG18 shielded |
mm2 |
2x0,75 |
| Sound power level |
dB(A) |
40 |
| Sound pressure 9 |
dB(A) |
ND |
| Dimensions (W x H x D) |
mm |
600x1683x600 |
| Dimension of Package (W x H x D) |
mm |
730x1920x730 |
| Circulation pump |
Type |
DC, electronic |
| Maximum lifting height |
m |
9 |
| Power |
W |
5~90 |
| Minimum water flow |
m3/h |
0,36 |
| Operating limits for water flow |
m3/h |
0,4 ~ 2,1 |
| Heat exchanger |
Plate |
| Expansion tank |
l |
8 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
9,52 (3/8") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Water pipe connection |
Heating/cooling |
R1" |
| Hot water preparation |
R3/4" |
| Net / Gross weight |
|
kg |
139 / 154 |
| Supply water temperature |
Heating |
°C |
+12 ~ +65 |
| Cooling |
°C |
+5 ~ +30 |
| Hot water preparation |
°C |
+12 ~ +60 |
| Ambient temperature |
°C |
+5 ~ +35 |
| Water pressure in the heating/cooling system |
bar |
1 ~ 2,5 |
| Water pressure in the hot water system (cold water) |
bar |
1,5 ~ 3 |
1 Air temperature +7°C, 85% RH, water temperature +30/35°C.
2 Air temperature +7°C, 85% RH,
water temperature +40/45°C.
3 Air temperature +7°C, 85% RH, water temperature +47/55°C.
4 Air temperature -7°C, 85% RH, water temperature +30/35°C.
5 OAir temperature +35°C, water temperature +23/18°C.
6 Air temperature +35°C, water temperature +12/7°C.
7 Determined in temperate climate conditions.
8 Tested according to EN12102-1 standard.
9 The maximum sound pressure value tested under two conditions is A7W35 for heating and A35W18 for
cooling.
| Outdoor units |
|
HOP10WODU |
| Heating A7W35 1 |
Power |
kW |
10,00 |
| Energy consumption |
kW |
2,00 |
| COP |
5,00 |
| Heating A7W45 2 |
Power |
kW |
10,00 |
| Energy consumption |
kW |
2,63 |
| COP |
3,80 |
| Heating A7W55 3 |
Power |
kW |
9,50 |
| Energy consumption |
kW |
3,06 |
| COP |
3,10 |
| Heating A-7W35 4 |
Power |
kW |
8,25 |
| Energy consumption |
kW |
2,62 |
| COP |
3,15 |
| Cooling A35W18 5 |
Power |
kW |
10,00 |
| Energy consumption |
kW |
2,08 |
| EER |
4,80 |
| Cooling A35W7 6 |
Power |
kW |
8,20 |
| Energy consumption |
kW |
2,48 |
| EER |
3,30 |
| Energy efficiency class 7 |
Water temperature 35°C |
class |
A+++ |
| Water temperature 55°C |
class |
A++ |
| SCOP 7 |
35°C |
5,2 |
| 55°C |
3,47 |
| SEER 7 |
7°C |
5,98 |
| 18°C |
8,78 |
| Power supply |
V/Ph/Hz |
220-240/1/50 |
| Rated power |
W |
3600 |
| Rated current |
A |
16,0 |
| Automatic switch |
C20 ~1 |
| Power cable |
mm2 |
3x2,5 |
| Refrigerant |
Type (GWP) |
R32 (675) |
| Quantity in the device |
kg |
1,65 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
9,52 (3/8") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Between the indoor and outdoor blocks |
Height difference, max. |
m |
20 |
| Track length, min. |
m |
3 |
| Track length, max. |
m |
30 |
| Refrigerant replenishment |
Quantity |
g/m |
38 |
| Pipe length |
m |
max.15 |
| Compressor |
DC two rotor inverter |
| Fan |
DC electric motor |
| Sound power level 8 |
dB(A) |
60 |
| Sound pressure (at a distance of 1m) 9 |
dB(A) |
49 |
| Sound pressure (1m away, silent mode) 9 |
dB(A) |
41 |
| Dimensions (W x H x D) |
mm |
1118×865×523 |
| Dimension of Package (W x H x D) |
mm |
1190×970×560 |
| Net / Gross weight |
|
kg |
75 / 89 |
| Outdoor operating temperature limits |
Heating |
°C |
-25 ~ +35 |
| Cooling |
°C |
-5 ~ +43 |
| Hot water preparation |
°C |
-25 ~ +43 |
|
|
|
|
| Indoor units with built-in hot water
tank |
HOP100/190IDU |
| Efficiency class for hot potable water treatment
(temperate zone) |
class |
A+ |
| COP |
3,02 |
| Declared load profile |
L |
| Water tank capacity |
Capacity |
l |
190 |
| Material |
- |
Stainless Steel, SUS 316L |
| Max water temperature |
°C |
70 |
| Isolation |
- |
Polyurethane |
| Built-in electric heater |
kW |
3 |
| Power supply |
V/Ph/Hz |
220-240/1/50 |
| Rated power |
W |
3095 |
| Rated current |
A |
13,5 |
| Power cable |
mm2 |
3x2,5 |
| Communication cable, AWG18 shielded |
mm2 |
2x0,75 |
| Sound power level |
dB(A) |
40 |
| Sound pressure 9 |
dB(A) |
ND |
| Dimensions (W x H x D) |
mm |
600x1683x600 |
| Dimension of Package (W x H x D) |
mm |
730x1920x730 |
| Circulation pump |
Type |
DC, electronic |
| Maximum lifting height |
m |
9 |
| Power |
W |
5~90 |
| Minimum water flow |
m3/h |
0,36 |
| Operating limits for water flow |
m3/h |
0,4 ~ 2,1 |
| Heat exchanger |
Plate |
| Expansion tank |
l |
8 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
9,52 (3/8") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Water pipe connection |
Heating/cooling |
R1" |
| Hot water preparation |
R3/4" |
| Net / Gross weight |
|
kg |
140 / 161 |
| Supply water temperature |
Heating |
°C |
+12 ~ +65 |
| Cooling |
°C |
+5 ~ +30 |
| Hot water preparation |
°C |
+12 ~ +60 |
| Ambient temperature |
°C |
+5 ~ +35 |
| Water pressure in the heating/cooling system |
bar |
1 ~ 2,5 |
| Water pressure in the hot water system (cold water) |
bar |
1,5 ~ 3 |
1 Air temperature +7°C, 85% RH, water temperature +30/35°C.2 Air temperature +7°C, 85% RH,
water temperature +40/45°C.
3 Air temperature +7°C, 85% RH, water temperature +47/55°C.
4 Air temperature -7°C, 85% RH, water temperature +30/35°C.
5 Air temperature +35°C, water temperature +23/18°C.
6 Air temperature +35°C, water temperature +12/7°C.
7 Determined in temperate climate conditions.
8 Tested according to EN12102-1 standard.
9 The maximum sound pressure value tested under two conditions is A7W35 for heating and A35W18 for
cooling.
| Outdoor units |
|
HOP10WODU |
| Heating A7W35 1 |
Power |
kW |
10,00 |
| Energy consumption |
kW |
2,00 |
| COP |
5,00 |
| Heating A7W45 2 |
Power |
kW |
10,00 |
| Energy consumption |
kW |
2,63 |
| COP |
3,80 |
| Heating A7W55 3 |
Power |
kW |
9,50 |
| Energy consumption |
kW |
3,06 |
| COP |
3,10 |
| Heating A-7W35 4 |
Power |
kW |
8,25 |
| Energy consumption |
kW |
2,62 |
| COP |
3,15 |
| Cooling A35W18 5 |
Power |
kW |
10,00 |
| Energy consumption |
kW |
2,08 |
| EER |
4,80 |
| Cooling A35W7 6 |
Power |
kW |
8,20 |
| Energy consumption |
kW |
2,48 |
| EER |
3,30 |
| Energy efficiency class 7 |
Water temperature 35°C |
class |
A+++ |
| Water temperature 55°C |
class |
A++ |
| SCOP 7 |
35°C |
5,2 |
| 55°C |
3,47 |
| SEER 7 |
7°C |
5,98 |
| 18°C |
8,78 |
| Power supply |
V/Ph/Hz |
220-240/1/50 |
| Rated power |
W |
3600 |
| Rated current |
A |
16,0 |
| Automatic switch |
C20 ~1 |
| Power cable |
mm2 |
3x2,5 |
| Refrigerant |
Type (GWP) |
R32 (675) |
| Quantity in the device |
kg |
1,65 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
9,52 (3/8") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Between the indoor and outdoor blocks |
Height difference, max. |
m |
20 |
| Pipe length, min. |
m |
3 |
| Pipe length, max. |
m |
30 |
| Additional Refrigerant Charge |
Quantity |
g/m |
38 |
| Pipe Length without Additional Charge |
m |
max.15 |
| Compressor |
DC two rotor inverter |
| Fan |
DC electric motor |
| Sound power level 8 |
dB(A) |
60 |
| Sound pressure (at a distance of 1m) 9 |
dB(A) |
49 |
| Sound pressure (1m away, silent mode) 9 |
dB(A) |
41 |
| Dimensions (W x H x D) |
mm |
1118×865×523 |
| Dimension of Package (W x H x D) |
mm |
1190×970×560 |
| Net / Gross weight |
|
kg |
75/89 |
| Outdoor operating temperature limits |
Heating |
°C |
-25 ~ +35 |
| Cooling |
°C |
-5 ~ +43 |
| Hot water preparation |
°C |
-25 ~ +43 |
|
|
|
|
| Indoor units with built-in hot water
tank |
HOP100/190IDU3 |
| Efficiency class for hot potable water treatment
(temperate zone) |
class |
A+ |
| COP |
3,02 |
| Declared load profile |
L |
| Water tank capacity |
Capacity |
l |
190 |
| Material |
- |
Stainless Steel, SUS 316L |
| Max water temperature |
°C |
70 |
| Isolation |
- |
Polyurethane |
| Built-in electric heater |
kW |
9 (3+3+3)8 |
| Power supply |
V/Ph/Hz |
380-415/3/50 |
| Rated power |
W |
9095 |
| Rated current |
A |
13,5 |
| Power cable |
mm2 |
5x2,5 |
| Communication cable, AWG18 shielded |
mm2 |
2x0,75 |
| Sound power level |
dB(A) |
40 |
| Sound pressure 9 |
dB(A) |
ND |
| Dimensions (W x H x D) |
mm |
600x1683x600 |
| Dimension of Package (W x H x D) |
mm |
730x1920x730 |
| Circulation pump |
Type |
DC, electronic |
| Maximum lifting height |
m |
9 |
| Power |
W |
5~90 |
| Minimum water flow |
m3/h |
0,36 |
| Operating limits for water flow |
m3/h |
0,4 ~ 2,1 |
| Heat exchanger |
Plate |
| Expansion tank |
l |
8 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
9,52 (3/8") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Water pipe connection |
Heating/cooling |
R1" |
| Hot water preparation |
R3/4" |
| Net / Gross weight |
|
kg |
139 / 154 |
| Supply water temperature |
Heating |
°C |
+12 ~ +65 |
| Cooling |
°C |
+5 ~ +30 |
| Hot water preparation |
°C |
+12 ~ +60 |
| Ambient temperature |
°C |
+5 ~ +35 |
| Water pressure in the heating/cooling system |
bar |
1 ~ 2,5 |
| Water pressure in the hot water system (cold water) |
bar |
1,5 ~ 3 |
1 Air temperature +7°C, 85% RH, water temperature +30/35°C.2 Air temperature +7°C, 85% RH,
water temperature +40/45°C.
3 Air temperature +7°C, 85% RH, water temperature +47/55°C.
4 Air temperature -7°C, 85% RH, water temperature +30/35°C.
5 Air temperature +35°C, water temperature +23/18°C.
6 Air temperature +35°C, water temperature +12/7°C.
7 Determined in temperate climate conditions.
8 Tested according to EN12102-1 standard.
9 The maximum sound pressure value tested under two conditions is A7W35 for heating and A35W18 for
cooling.
| Outdoor units |
|
HOP12WODU3 |
| Heating A7W35 1 |
Power |
kW |
12,10 |
| Energy consumption |
kW |
2,44 |
| COP |
4,95 |
| Heating A7W45 2 |
Power |
kW |
12,30 |
| Energy consumption |
kW |
3,24 |
| COP |
3,80 |
| Heating A7W55 3 |
Power |
kW |
12,00 |
| Energy consumption |
kW |
3,87 |
| COP |
3,10 |
| Heating A-7W35 4 |
Power |
kW |
10,00 |
| Energy consumption |
kW |
3,33 |
| COP |
3,00 |
| Cooling A35W18 5 |
Power |
kW |
12,00 |
| Energy consumption |
kW |
3,00 |
| EER |
4,00 |
| Cooling A35W7 6 |
Power |
kW |
11,60 |
| Energy consumption |
kW |
4,22 |
| EER |
2,75 |
| Energy efficiency class 7 |
Water temperature 35°C |
class |
A+++ |
| Water temperature 55°C |
class |
A++ |
| SCOP 7 |
35°C |
4,81 |
| 55°C |
3,45 |
| SEER 7 |
7°C |
4,86 |
| 18°C |
7,04 |
| Power supply |
V/Ph/Hz |
380-415/3/50 |
| Rated power |
W |
5400 |
| Rated current |
A |
9,0 |
| Automatic switch |
C16 ~3 |
| Power cable |
mm2 |
5x2,5 |
| Refrigerant |
Type (GWP) |
R32 (675) |
| Quantity in the device |
kg |
1,84 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
9,52 (3/8") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Between the indoor and outdoor blocks |
Height difference, max. |
m |
20 |
| Track length, min. |
m |
3 |
| Track length, max. |
m |
30 |
| Refrigerant replenishment |
Quantity |
g/m |
38 |
| Pipe length |
m |
max.15 |
| Compressor |
DC two rotor inverter |
| Fan |
DC electric motor |
| Sound power level 8 |
dB(A) |
64 |
| Sound pressure (at a distance of 1m) 9 |
dB(A) |
50 |
| Sound pressure (1m away, silent mode) 9 |
dB(A) |
43 |
| Dimensions (W x H x D) |
mm |
1118×865×523 |
| Dimension of Package (W x H x D) |
mm |
1190×970×560 |
| Net / Gross weight |
|
kg |
112 / 125.5 |
| Outdoor operating temperature limits |
Heating |
°C |
-25 ~ +35 |
| Cooling |
°C |
-5 ~ +43 |
| Hot water preparation |
°C |
-25 ~ +43 |
| Indoor units with built-in hot water
tank |
HOP160/240IDU3 |
| Efficiency class for hot potable water treatment
(temperate zone) |
class |
A+ |
| COP |
3,00 |
| Declared load profile |
XL |
| Water tank capacity |
Capacity |
l |
240 |
| Material |
- |
Stainless Steel, SUS 316L |
| Max water temperature |
°C |
70 |
| Isolation |
- |
Polyurethane |
| Built-in electric heater |
kW |
9 (3+6) 10 |
| Power supply |
V/Ph/Hz |
380-415/3/50 |
| Rated power |
W |
9095 |
| Rated current |
A |
13,5 |
| Power cable |
mm2 |
5x2,5 |
| Communication cable, AWG18 shielded |
mm2 |
2x0,75 |
| Sound power level |
dB(A) |
44 |
| Sound pressure 9 |
dB(A) |
ND |
| Dimensions (W x H x D) |
mm |
600x1943x600 |
| Dimension of Package (W x H x D) |
mm |
653x2160x653 |
| Circulation pump |
Type |
DC, electronic |
| Maximum lifting height |
m |
9 |
| Power |
W |
5~90 |
| Minimum water flow |
m3/h |
0,6 |
| Operating limits for water flow |
m3/h |
0,7 ~ 3,0 |
| Heat exchanger |
Plate, soldered |
| Expansion tank |
l |
8 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
9,52 (3/8") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Water pipe connection |
Heating/cooling |
R1" |
| Hot water preparation |
R3/4" |
| Net / Gross weight |
|
kg |
159 / 180 |
| Supply water temperature |
Heating |
°C |
+12 ~ +65 |
| Cooling |
°C |
+5 ~ +30 |
| Hot water preparation |
°C |
+12 ~ +60 |
| Ambient temperature |
°C |
+5 ~ +35 |
| Water pressure in the heating/cooling system |
bar |
1 ~ 2,5 |
| Water pressure in the hot water system (cold water) |
bar |
1,5 ~ 3 |
1 Air temperature +7°C, 85% RH, water temperature +30/35°C.
2 Air temperature +7°C, 85% RH,
water temperature +40/45°C.3 Air temperature +7°C, 85% RH, water temperature +47/55°C.4 Air temperature -7°C, 85% RH, water temperature +30/35°C.
5 Air temperature +35°C, water temperature +23/18°C.
6 Air temperature +35°C, water temperature +12/7°C.
7 Determined in temperate climate conditions.
8 Tested according to EN12102-1 standard.
9 In the MONO unit, the maximum hot water temperature of 60°C can only be reached by using an
additional electric heater.
| Outdoor units |
|
HOP16WODU3 |
| Heating A7W35 1 |
Power |
kW |
16,00 |
| Energy consumption |
kW |
3,56 |
| COP |
4,50 |
| Heating A7W45 2 |
Power |
kW |
16,00 |
| Energy consumption |
kW |
4,44 |
| COP |
3,60 |
| Heating A7W55 3 |
Power |
kW |
16,00 |
| Energy consumption |
kW |
5,52 |
| COP |
2,90 |
| Heating A-7W35 4 |
Power |
kW |
13,30 |
| Energy consumption |
kW |
4,93 |
| COP |
2,70 |
| Cooling A35W18 5 |
Power |
kW |
14,90 |
| Energy consumption |
kW |
4,38 |
| EER |
3,40 |
| Cooling A35W7 6 |
Power |
kW |
14,00 |
| Energy consumption |
kW |
5,71 |
| EER |
2,45 |
| Energy efficiency class 7 |
Water temperature 35°C |
class |
A+++ |
| Water temperature 55°C |
class |
A++ |
| SCOP 7 |
35°C |
4,62 |
| 55°C |
3,41 |
| SEER 7 |
7°C |
4,67 |
| 18°C |
6,71 |
| Power supply |
V/Ph/Hz |
380-415/3/50 |
| Rated power |
W |
6100 |
| Rated current |
A |
11,0 |
| Automatic switch |
C16 ~3 |
| Power cable |
mm2 |
5x2,5 |
| Refrigerant |
Type (GWP) |
R32 (675) |
| Quantity in the device |
kg |
1,84 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
9,52 (3/8") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Between the indoor and outdoor blocks |
Height difference, max. |
m |
20 |
| Track length, min. |
m |
3 |
| Track length, max. |
m |
30 |
| Refrigerant replenishment |
Quantity |
g/m |
38 |
| Pipe length |
m |
max.15 |
| Compressor |
DC two rotor inverter |
| Fan |
DC electric motor |
| Sound power level 8 |
dB(A) |
68 |
| Sound pressure (at a distance of 1m) 9 |
dB(A) |
55 |
| Sound pressure (1m away, silent mode) 9 |
dB(A) |
43 |
| Dimensions (W x H x D) |
mm |
1118×865×523 |
| Dimension of Package (W x H x D) |
mm |
1190×970×560 |
| Net / Gross weight |
|
kg |
116 / 129,5 |
| Outdoor operating temperature limits |
Heating |
°C |
-25 ~ +35 |
| Cooling |
°C |
-5 ~ +43 |
| Hot water preparation |
°C |
-25 ~ +43 |
|
|
|
|
| Indoor units with built-in hot water
tank |
HOP160/240IDU3 |
| Efficiency class for hot potable water treatment
(temperate zone) |
class |
A+ |
| COP |
3,00 |
| Declared load profile |
XL |
| Water tank capacity |
Capacity |
l |
240 |
| Material |
- |
Stainless Steel, SUS 316L |
| Max water temperature |
°C |
70 |
| Isolation |
- |
Polyurethane |
| Built-in electric heater |
kW |
9 (3+3+3)8 |
| Power supply |
V/Ph/Hz |
380-415/3/50 |
| Rated power |
W |
9095 |
| Rated current |
A |
13,5 |
| Power cable |
mm2 |
5x2,5 |
| Communication cable, AWG18 shielded |
mm2 |
2x0,75 |
| Sound power level7 |
dB(A) |
44 |
| Sound pressure |
dB(A) |
ND |
| Dimensions (W x H x D) |
mm |
600x1943x600 |
| Dimension of Package (W x H x D) |
mm |
730x2182x730 |
| Circulation pump |
Type |
DC, electronic |
| Maximum lifting height |
m |
9 |
| Power |
W |
5~90 |
| Minimum water flow |
m3/h |
0,6 |
| Operating limits for water flow |
m3/h |
0,7 ~ 3,0 |
| Heat exchanger |
Plate |
| Expansion tank |
l |
8 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
9,52 (3/8") |
| Gas-phase |
mm (col) |
15,88 (5/8") |
| Water pipe connection |
Heating/cooling |
R1" |
| Hot water preparation |
R3/4" |
| Net / Gross weight |
|
kg |
159 / 180 |
| Supply water temperature |
Heating |
°C |
+12 ~ +65 |
| Cooling |
°C |
+5 ~ +30 |
| Hot water preparation |
°C |
+12 ~ +60 |
| Ambient temperature |
°C |
+5 ~ +35 |
| Water pressure in the heating/cooling system |
bar |
1 ~ 2,5 |
| Water pressure in the hot water system (cold water) |
bar |
1,5 ~ 3 |
1 Air temperature +7°C, 85% RH, water temperature +30/35°C.
2
Air temperature +7°C, 85% RH, water temperature +40/45°C.3 Air temperature +7°C, 85% RH, water temperature +47/55°C.4 Air temperature -7°C, 85% RH, water temperature +30/35°C.5 Air temperature +35°C, water temperature +23/18°C.6 Air temperature +35°C, water temperature +12/7°C.
7 Determined in temperate climate conditions.
8 Tested according to EN12102-1 standard.
9 In the MONO unit, the maximum hot water temperature of 60°C can only be reached by using an
additional electric heater.